EMC PARTNER France |
|
Mieux vous informer. |
|
La liste de tous les produits pour TRA2006 et TRA3000 |
|
|
|
Pour toutes les documentations et logiciels de démonstrations : Allez sur le Site Officiel de EMC PARTNER A.G. |
|
|
|
|
TRA2006 E-F-S-D |
TRA2000IN6 version: ESD control and HVsource up to 15kV; |
|
|
EFT (4.4kV) 1MHz burst; SURGE 1.2/50µs (6.1kV), |
|
|
8/20µs (3.05kA); DIPS up to 16A; Variation up to 6A. |
|
TRA2006 E-F-S-D-R |
TRA2000IN6 full version: ESD control and HV source |
|
|
up to 15kV; EFT (4.4kV). 1MHz burst ; SURGE 1.2/50µs (6.1kV), |
|
|
8/20µs (3.05kA); DIPS up to 16A; Variation up to 6A; |
|
|
Ring wave 100kHz (6kV). |
|
TRA2006 E-F-S-R |
TRA2000IN6 version: ESD control and HV source up to 15kV; |
|
|
EFT (4.4kV), 1MHz burst; SURGE 1.2/50µs (6.1kV), |
|
|
8/20µs (3.05kA); Ring wave 100kHz (6kV). |
|
TRA2006 E-F-S-T-D |
TRA2000IN6 version: ESD control and HV source; EFT (4.4kV), |
|
|
1MHz burst; SURGE 1.2/50µs (6.1kV), 8/20µs (3.05kA); |
|
|
10/700 (6kV); Variation up to 6A; DIPS up to 16A. |
|
TRA2006 E-S |
TRA2000IN6 version: ESD control and HV source |
|
|
up to 15kV; SURGE 1.2/50µs (6.1kV), 8/20µs (3.05kA). |
|
TRA2006 F-S |
TRA2000IN6 version: EFT (4.4kV), 1MHz burst; |
|
|
SURGE 1.2/50µs (6.1kV), 8/20µs (3.05kA). |
|
TRA2006 F-S-D-R |
TRA2000IN6 version: EFT (4.4kV), 1MHz burst; |
|
|
SURGE 1.2/50µs (6.1kV), 8/20µs (3.05kA); DIPS up to 16A; |
|
|
Variation up to 6A; Ring wave 100kHz (6kV). |
|
TRA2006 F-S-R |
TRA2000IN6 version: EFT (4.4kV), 1MHz burst; |
|
|
SURGE 1.2/50µs (6.1kV), 8/20µs (3.05kA); |
|
|
Ring wave 100kHz (6kV). |
|
TRA2006 F-S-T |
TRA2000IN6 version: EFT(4.4kV), 1MHz burst; |
|
|
SURGE 1.2/50µs (6.1kV), 8/20µs; 10/700µs (6kV) |
|
TRA2006 S-D-R |
TRA2000IN6 version: SURGE 1.2/50µs (6.1kV), |
|
|
8/20µs (3.05kA); DIPS up to 16A; Variation up to 6A; |
|
|
Ring wave 100kHz (6kV). |
|
|
|
|
Type |
Short Description |
|
EXT-TRA3000 C |
TRA3000 Extension: Common Mode IEC 61000-4-16 Ed.1.2, |
|
|
up to 35V for all continuous a.c/d.c, frequency sweep up to 150kHz. |
|
|
Internal PCB. For short time test levels see accessories. |
|
EXT-TRA3000 C-SHORT |
Extends TRA3000 C with short test. EXT-TRA3000 C-SHORT |
|
|
consists of one external trafo box, 1x PS3 power supply, |
|
|
1x RS232/485 convertor to remote control the PS3 from TRA3000. |
|
|
Requires TRA3000 C. |
|
EXT-TRA3000 D |
TRA3000 Extension: DIPS IEC 61000-4-11 Ed.2. |
|
|
Interruption up to 16A. Internal PCB |
|
EXT-TRA3000 D-V-29D |
Extension to TRA3000 for d.c. dips and interruption according to |
|
|
IEC 61000-4-29. Consist of: 2 x PS3, 2 x RS232/485 converter |
|
|
to remote control PS3 from TRA3000. Requires TRA3000 D. |
|
EXT-TRA3000 D-V-29I |
Extension to TRA3000 for d.c. interruption according to |
|
|
IEC 61000-4-29. Consists of: 1 x PS3, 1 x RS232/485 converter |
|
|
to remote control PS3 from TRA3000. Requires TRA3000 D. |
|
EXT-TRA3000 E |
TRA3000 Extension: Electro Static Discharge, IEC 61000-4-2 Ed.2 |
|
|
150pF, 330 Ohm. AD up to 16kV, CD up to 10kV. |
|
|
External accessory. |
|
EXT-TRA3000 F |
TRA3000 Extension: Electric Fast Transient, IEC 61000-4-4 Ed.2 |
|
|
EFT (4.4kV), 1MHz burst. Internal PCB. |
|
EXT-TRA3000 S |
TRA3000 Extension: SURGE IEC 61000-4-5 Ed.2 |
|
|
CWG 1.2/50µs (4.1kV), 8/20µs (2.05kA). Internal PCB. |
|
EXT-TRA3000 V |
TRA3000 Extension: Voltage Variation up to 6A |
|
|
IEC 61000-4-11 Ed.1. Internal Variac. |
|
TRA3000 |
TRA3000 Mainframe. The mainframe includes: Control of ESD, EFT, |
|
|
CWG, DIPS, VARIAC, Common Mode, PS3, Display with keyboard, |
|
|
Control Ports: RS232, Ethernet, USB, Atmospheric sensors. |
|
|
Must be ordered with at least one EXT-TRA3000 X. |
|
TRA3000 C |
TRA3000 Version: Common Mode IEC 61000-4-16 Ed.1.2, |
|
|
up to 35V for all continuous a.c/d.c, frequency sweep |
|
|
up to 150kHz. For short time test levels see accessories. |
|
TRA3000 D |
TRA3000 Version: DIPS IEC 61000-4-11 Ed.2. |
|
|
Interruption up to 16A. |
|
TRA3000 D-V |
TRA3000 Version: DIPS IEC 61000-4-11 Ed.2. |
|
|
Interruption up to 16A; Variation up to 6A. |
|
TRA3000 D-V-C |
TRA3000 Version: DIPS IEC 61000-4-11 Ed.2. Interruption up to 16A; |
|
|
DIPS and Variation up to 6A, Common Mode IEC 61000-4-16 Ed.1.2, |
|
|
up to 35V for all continuous a.c/d.c, frequency sweep up to 150kHz |
|
|
For short time test levels see accessories. |
|
TRA3000 F |
TRA3000 Version: Electric Fast Transient, IEC 61000-4-4 Ed.2 |
|
|
EFT (4.4kV), 1MHz burst. |
|
TRA3000 F-D-V |
TRA3000 Version: Electric Fast Transient, IEC 61000-4-4 Ed.2 |
|
|
EFT (4.4kV), 1MHz burst, Interruption up to 16A; |
|
|
DIPS and Variation up to 6A, |
|
TRA3000 F-S |
TRA3000 Version: Electric Fast Transient, |
|
|
IEC 61000-4-4 Ed.2 EFT (4.4kV), 1MHz burst; |
|
|
SURGE IEC 61000-4-5 Ed.2 |
|
|
CWG 1.2/50µs (4.1kV), 8/20µs (2.05kA). |
|
TRA3000 F-S-C |
TRA3000 Version: Electric Fast Transient, IEC 61000-4-4 Ed.2 |
|
|
EFT (4.4kV), 1MHz burst, SURGE IEC 61000-4-5 Ed.2 CWG 1.2/50µs |
|
|
(4.1kV), 8/20µs (2.05kA), Common Mode IEC 61000-4-16 Ed.1.2, |
|
|
up to 35V for all continuous a.c/d.c, frequency sweep up to 150kHz. |
|
TRA3000 F-S-D-V |
TRA3000 Version: Electric Fast Transient, IEC 61000-4-4 Ed.2 |
|
|
EFT (4.4kV), 1MHz burst, SURGE IEC 61000-4-5 Ed.2 CWG 1.2/50µs |
|
|
(4.1kV), 8/20µs (2.05kA). Interruption up to 16A; DIPS and |
|
|
Variation up to 6A. |
|
TRA3000 F-S-D-V-C |
TRA3000 Version: Fast Transient, IEC 61000-4-4 Ed.2 EFT(4.4kV), |
|
|
1MHz burst, SURGE IEC 61000-4-5 Ed.2 CWG 1.2/50µs (4.1kV), 8/20µs |
|
|
(2.05kA). DIPS IEC 61000-4-11 Ed.2. Interr. up to 16A; Variation up to |
|
|
6A; CM IEC 61000-4-16 Ed.1.2, up to 35V for all continuous a.c/d.c,f. |
|
TRA3000 F-V |
TRA3000 Version: Electric Fast Transient, |
|
|
IEC 61000-4-4 Ed.2 EFT (4.4kV), 1MHz burst |
|
|
Power supply variation with internal variac up to 6A. |
|
TRA3000 S |
TRA3000 Version: SURGE IEC 61000-4-5 Ed.2 |
|
|
CWG 1.2/50µs (4.1kV), 8/20µs (2.05kA). |
|
TRA3000 S-D-V |
TRA3000 Version: SURGE IEC 61000-4-5 Ed.2 |
|
|
CWG 1.2/50µs (4.1kV), 8/20µs (2.05kA). |
|
|
DIPS IEC 61000-4-11 Ed.2. Interruption up to 16A; |
|
|
DIPS and Variation up to 6A. |
|
TRA3000 S-D-V-C |
TRA3000 Version: SURGE IEC 61000-4-5 Ed.2 CWG 1.2/50µs (4.1kV), |
|
|
8/20µs (2.05kA). DIPS IEC 61000-4-11 Ed.2. Interruption up to 16A; |
|
|
DIPS and Variation up to 6A, Common Mode IEC 61000-4-16 Ed.1.2, |
|
|
up to 35V for all continuous a.c/d.c, frequency sweep up to 150kHz. |
|
TRA3000 S-V |
TRA3000 Version: SURGE IEC 61000-4-5 Ed.2 |
|
|
CWG 1.2/50µs (4.1kV), 8/20µs (2.05kA). |
|
|
Power supply variation with internal variac 6A. |
|
ADAPTER EFT-CDN |
Adapter for EFT calibration / verification at single or |
|
|
three phase CDN-EFT outputs. Remark: EFT measurement |
|
|
without power supply connected to CDN. |
|
CDN16-450C |
Single phase coupling decoupling filter for 115V, 400Hz to |
|
|
TRA2000 SURGE and EFT. Maximum current per phase 16A. |
|
CDN2000-06-32 |
Three phase CDN with line voltages L to N/PE=280V |
|
|
and L to L=415V, line current 32A per phase. Manual |
|
|
coupling path selection for EFT, SURGE and RING. |
|
CDN2000A-06-32 |
Three phase CDN with line voltages L to N/PE=280V and L to |
|
|
L=415V, line current 32A per phase. Automatic coupling path |
|
|
selection for EFT, SURGE and RING controlled by TRA2000, |
|
|
TRA2004, TRA2006, TRA3000 and MIG0603INx with SN > 199. |
|
CDN2000A-06-32 480V |
3 phase CDN with line voltages L to N/PE=280V and L to |
|
|
L=480V, line current 32A per phase. Automatic coupling path |
|
|
selection for EFT, SURGE and RING controlled by TRA2000, |
|
|
TRA2004, TRA2006, TRA3000 and MIG0603INx with SN > 199. |
|
CDN2000A-06-32 CMC |
3 phase CDN with line voltages L to N/PE=280V and L to |
|
|
L=480V, line current 32A per phase. Auto coupling path selection |
|
|
for EFT, SURGE, RING controlled by TRA2006 and MIG0603INx |
|
|
with S/N >199. Coupling path mode L1 + L2 + L3 + N to PE. |
|
CDN2000A-06-63 |
Three phase CDN with line voltages L to N/PE=280V and L |
|
|
to L=480V, line current 63A per phase. Automatic coupling |
|
|
path selection for EFT and SURGE controlled by TRA2000, |
|
|
TRA2004, TRA2006, TRA3000 and MIG0603INx with SN > 199. |
|
CDN-A-3P100-480 F |
Three phase CDN with line voltages L to N/PE=280V and L to L=480V, |
|
|
line current 100A per phase. Automatic coupling path selection |
|
|
for EFT controlled by TRA2000, TRA2004, TRA2006 and TRA3000. |
|
CDN-A-3P100-480 F-S |
Three phase CDN with line voltages L to N/PE=280V and L to L=480V, |
|
|
line current 100A per phase. Automatic coupling path selection for |
|
|
EFT and SURGE controlled by TRA2000, TRA2004, TRA2006, TRA3000 |
|
|
and MIG0603INx with SN > 199. |
|
CDN-A-3P100-690 F |
Three phase CDN with line voltages L to N/PE=398V and L to L=690V, |
|
|
line current 100A per phase. Automatic coupling path selection for EFT |
|
|
controlled by customized TRA2000, TRA2004, TRA2006 and TRA3000. |
|
|
The generator must be ordered together with the CDN. |
|
CDN-A-3P100-690 F-S |
Three phase CDN with line voltages L to N/PE=398V and L to L=690V, |
|
|
line current 100A/Phase. Automatic coupling path selection for EFTand |
|
|
SURGE controlled by customized TRA2000, TRA2004, TRA2006, TRA3000, |
|
|
and MIG0603INx with SN > 199. The generator must be ordered with CDN. |
|
CDN-KIT1000 |
SURGE coupling-decoupling network for data lines according |
|
|
to IEC 61000-4-5. |
|
CN16 |
Coupling network for common mode coupling dc, 50/60Hz |
|
|
and sinusoidal up to 150kHz according to IEC 61000-4-16. |
|
CN16T |
T-coupling network for telecom lines coupling dc, 50/60Hz |
|
|
and sinusoidal up to 150kHz according to IEC 61000-4-16. |
|
CN2000-22-5 |
One Coupling Module. Serial resistor 40 Ohm and |
|
|
capacitor 0.5µF. |
|
CN2000TT MC |
One test pistol and one banana plugged cable with crocodile |
|
|
clip for current injection tests according to IEC 61000-4-5 |
|
|
up to 3kA. The test pistol can be used together with TRA |
|
|
and MIG systems with MC plug outputs on front panel or NW. |
|
CN-BALUN |
Balanced / unbalanced transmission line transformer for |
|
|
EFT and 1MHz Damped Sine according to ANSI / IEEE C37.90. |
|
CN-EFT1000 |
Capacitive coupling clamp 100 Ohm according to IEC 61000-4-4 |
|
|
including 1m coax cable with BNC connectors. |
|
DIPS100E |
100 Ohm resistor for switching time calibration. Can be used |
|
|
with TRA1000, TRA2000, TRA3000, PFS32, PFS63. |
|
|
100 Ohm +/-5%, 1 kW. |
|
DN2000-22-5 |
One Decoupling Module for IEC 60255-22-5 application. |
|
|
Inductance 20mH, varistor at the auxiliary side 275V, |
|
|
Imax continuous 3A, intermittant use 10mn 5A. |
|
EFT INSULATION |
Set of 2 x 10cm Insulation to EFT circuit according to |
|
|
IEC 61000-4-4. |
|
ESD2000 |
ESD discharge network 150pF - 330 Ohm. Contact discharge up to |
|
|
10kV, air discharge up to 16kV according to IEC 61000-4-2 Ed.2. |
|
|
Stand available under ESD3000 System, product type ESD-STAND Ed2. |
|
|
For use with TRA2000, TRA2004 and TRA2006 only. |
|
MF1000-1 |
Test coil 1m x 1m for magnetic field test: |
|
|
50/60Hz according to IEC 61000-4-8, |
|
|
SURGE according to IEC 61000-4-9, |
|
|
Damped oscillatory wave according to IEC 61000-4-10. |
|
MF1000-2 |
Test coil 1m x 2.6m for magnetic field test: |
|
|
50/60Hz according toIEC 61000-4-8, |
|
|
SURGE according to IEC 61000-4-9, |
|
|
Damped ocillatory wave according to IEC 61000-4-10. |
|
MF1000-3 |
Test coil 1m x 1m for magnetic field test according to |
|
|
IEC 61000-4-8 only for short duration 3s 1000A/m. |
|
MF1STAND |
Stand to MF1000-1, moveable in all three directions, |
|
|
max height 1.8m. Must be ordered together with the |
|
|
MF1000-1. Can only be shipped together with the MF1000-1. |
|
MF3STAND |
Stand to MF1000-3, moveable in two directions, max. |