TRA2000IN6 version: ESD control and HVsource up to 15kV;

 

EFT (4.4kV) 1MHz burst; SURGE 1.2/50µs (6.1kV),

 

8/20µs (3.05kA); DIPS up to 16A; Variation up to 6A.

TRA2006 E-F-S-D-R

TRA2000IN6 full version: ESD control and HV source

 

up to 15kV; EFT (4.4kV). 1MHz burst ; SURGE 1.2/50µs (6.1kV),

 

8/20µs (3.05kA); DIPS up to 16A; Variation up to 6A;

 

Ring wave 100kHz (6kV).

TRA2006 E-F-S-R

TRA2000IN6 version: ESD control and HV source up to 15kV;

 

EFT (4.4kV), 1MHz burst; SURGE 1.2/50µs (6.1kV),

 

8/20µs (3.05kA); Ring wave 100kHz (6kV).

TRA2006 E-F-S-T-D

TRA2000IN6 version: ESD control and HV source; EFT (4.4kV),

 

1MHz burst; SURGE 1.2/50µs (6.1kV), 8/20µs (3.05kA); 

 

10/700 (6kV); Variation up to 6A; DIPS up to 16A.

TRA2006 E-S

TRA2000IN6 version: ESD control and HV source

 

up to 15kV; SURGE 1.2/50µs (6.1kV), 8/20µs (3.05kA).

TRA2006 F-S

TRA2000IN6 version: EFT (4.4kV), 1MHz burst;

 

SURGE 1.2/50µs (6.1kV), 8/20µs (3.05kA).

TRA2006 F-S-D-R

TRA2000IN6 version: EFT (4.4kV), 1MHz burst;

 

SURGE 1.2/50µs (6.1kV), 8/20µs (3.05kA); DIPS up to 16A;

 

Variation up to 6A; Ring wave 100kHz (6kV).

TRA2006 F-S-R

TRA2000IN6 version: EFT (4.4kV), 1MHz burst;

 

SURGE 1.2/50µs (6.1kV), 8/20µs (3.05kA);

 

Ring wave 100kHz (6kV).

TRA2006 F-S-T

TRA2000IN6 version: EFT(4.4kV), 1MHz burst; 

 

SURGE 1.2/50µs (6.1kV), 8/20µs; 10/700µs (6kV)

TRA2006 S-D-R

TRA2000IN6 version: SURGE 1.2/50µs (6.1kV),

 

8/20µs (3.05kA); DIPS up to 16A; Variation up to 6A;

 

Ring wave 100kHz (6kV).

 

 

Type

Short Description

EXT-TRA3000 C

TRA3000 Extension: Common Mode IEC 61000-4-16 Ed.1.2,

 

up to 35V for all continuous a.c/d.c, frequency sweep up to 150kHz.

 

Internal PCB. For short time test levels see accessories.

EXT-TRA3000 C-SHORT

Extends TRA3000 C with short test. EXT-TRA3000 C-SHORT

 

consists of one external trafo box, 1x PS3 power supply,

 

1x RS232/485 convertor to remote control the PS3 from TRA3000.

 

Requires TRA3000 C.

EXT-TRA3000 D

TRA3000 Extension: DIPS IEC 61000-4-11 Ed.2.

 

Interruption up to 16A. Internal PCB

EXT-TRA3000 D-V-29D

Extension to TRA3000 for d.c. dips and interruption according to

 

IEC 61000-4-29. Consist of: 2 x PS3, 2 x RS232/485 converter

 

to remote control PS3 from TRA3000. Requires TRA3000 D.

EXT-TRA3000 D-V-29I

Extension to TRA3000 for d.c. interruption according to

 

IEC 61000-4-29. Consists of: 1 x PS3, 1 x RS232/485 converter 

 

to remote control PS3 from TRA3000. Requires TRA3000 D.

EXT-TRA3000 E

TRA3000 Extension: Electro Static Discharge, IEC 61000-4-2 Ed.2

 

150pF, 330 Ohm. AD up to 16kV, CD up to 10kV.

 

External accessory.

EXT-TRA3000 F

TRA3000 Extension: Electric Fast Transient, IEC 61000-4-4 Ed.2

 

EFT (4.4kV), 1MHz burst. Internal PCB.

EXT-TRA3000 S

TRA3000 Extension: SURGE IEC 61000-4-5 Ed.2

 

CWG 1.2/50µs (4.1kV), 8/20µs (2.05kA). Internal PCB.

EXT-TRA3000 V

TRA3000 Extension: Voltage Variation up to 6A

 

IEC 61000-4-11 Ed.1. Internal Variac.

TRA3000

TRA3000 Mainframe. The mainframe includes: Control of ESD, EFT,

 

CWG, DIPS, VARIAC, Common Mode, PS3, Display with keyboard,

 

Control Ports: RS232, Ethernet, USB, Atmospheric sensors. 

 

Must be ordered with at least one EXT-TRA3000 X.

TRA3000 C

TRA3000 Version: Common Mode IEC 61000-4-16 Ed.1.2,

 

up to 35V for all continuous a.c/d.c, frequency sweep

 

up to 150kHz. For short time test levels see accessories.

TRA3000 D

TRA3000 Version: DIPS IEC 61000-4-11 Ed.2.

 

Interruption up to 16A.

TRA3000 D-V

TRA3000 Version: DIPS IEC 61000-4-11 Ed.2.

 

Interruption up to 16A;  Variation up to 6A.

TRA3000 D-V-C

TRA3000 Version: DIPS IEC 61000-4-11 Ed.2. Interruption up to 16A;

 

DIPS and Variation up to 6A, Common Mode IEC 61000-4-16 Ed.1.2,

 

up to 35V for all continuous a.c/d.c, frequency sweep up to 150kHz

 

For short time test levels see accessories.

TRA3000 F

TRA3000 Version: Electric Fast Transient, IEC 61000-4-4 Ed.2

 

EFT (4.4kV), 1MHz burst.

TRA3000 F-D-V

TRA3000 Version: Electric Fast Transient, IEC 61000-4-4 Ed.2

 

EFT (4.4kV), 1MHz burst, Interruption up to 16A;

 

DIPS and Variation up to 6A,

TRA3000 F-S

TRA3000 Version: Electric Fast Transient,

 

IEC 61000-4-4 Ed.2 EFT (4.4kV), 1MHz burst;

 

SURGE IEC 61000-4-5 Ed.2 

 

CWG 1.2/50µs (4.1kV), 8/20µs (2.05kA).

TRA3000 F-S-C

TRA3000 Version: Electric Fast Transient, IEC 61000-4-4 Ed.2

 

EFT (4.4kV), 1MHz burst, SURGE IEC 61000-4-5 Ed.2 CWG 1.2/50µs

 

(4.1kV), 8/20µs (2.05kA), Common Mode IEC 61000-4-16 Ed.1.2,

 

up to 35V for all continuous a.c/d.c, frequency sweep up to 150kHz.

TRA3000 F-S-D-V

TRA3000 Version: Electric Fast Transient, IEC 61000-4-4 Ed.2

 

EFT (4.4kV), 1MHz burst, SURGE IEC 61000-4-5 Ed.2 CWG 1.2/50µs

 

(4.1kV), 8/20µs (2.05kA). Interruption up to 16A; DIPS and

 

Variation up to 6A.

TRA3000 F-S-D-V-C

TRA3000 Version: Fast Transient, IEC 61000-4-4 Ed.2 EFT(4.4kV),

 

1MHz burst, SURGE IEC 61000-4-5 Ed.2 CWG 1.2/50µs (4.1kV), 8/20µs

 

(2.05kA). DIPS IEC 61000-4-11 Ed.2. Interr. up to 16A; Variation up to

 

6A; CM IEC 61000-4-16 Ed.1.2, up to 35V for all continuous a.c/d.c,f.

TRA3000 F-V

TRA3000 Version: Electric Fast Transient,

 

IEC 61000-4-4 Ed.2 EFT (4.4kV), 1MHz burst

 

Power supply variation with internal variac up to 6A.

TRA3000 S

TRA3000 Version: SURGE IEC 61000-4-5 Ed.2 

 

CWG 1.2/50µs (4.1kV), 8/20µs (2.05kA).

TRA3000 S-D-V

TRA3000 Version: SURGE  IEC 61000-4-5 Ed.2

 

CWG 1.2/50µs (4.1kV), 8/20µs (2.05kA).

 

DIPS  IEC 61000-4-11 Ed.2. Interruption up to 16A;

 

DIPS and Variation up to 6A.

TRA3000 S-D-V-C

TRA3000 Version: SURGE IEC 61000-4-5 Ed.2 CWG 1.2/50µs (4.1kV),

 

8/20µs (2.05kA). DIPS IEC 61000-4-11 Ed.2. Interruption up to 16A;

 

DIPS and Variation up to 6A, Common Mode IEC 61000-4-16 Ed.1.2,

 

up to 35V for all continuous a.c/d.c, frequency sweep up to 150kHz.

TRA3000 S-V

TRA3000 Version: SURGE IEC 61000-4-5 Ed.2

 

CWG 1.2/50µs (4.1kV), 8/20µs (2.05kA).

 

Power supply variation with internal variac 6A.

ADAPTER EFT-CDN

Adapter for EFT calibration / verification at single or

 

three phase CDN-EFT outputs. Remark: EFT measurement

 

without power supply connected to CDN.

CDN16-450C

Single phase coupling decoupling filter for 115V, 400Hz to

 

TRA2000 SURGE and EFT. Maximum current per phase 16A.

CDN2000-06-32

Three phase CDN with line voltages L to N/PE=280V

 

and L to L=415V,  line current 32A per phase. Manual

 

coupling path selection for EFT, SURGE and RING.

CDN2000A-06-32

Three phase CDN with line voltages L to N/PE=280V and L to

 

L=415V, line current 32A per phase. Automatic coupling path

 

selection for EFT, SURGE and RING controlled by TRA2000,

 

TRA2004, TRA2006, TRA3000 and MIG0603INx with SN > 199.

CDN2000A-06-32 480V

3 phase CDN with line voltages L to N/PE=280V and L to

 

L=480V, line current 32A per phase. Automatic coupling path

 

selection for EFT, SURGE and RING controlled by TRA2000,

 

TRA2004, TRA2006, TRA3000 and MIG0603INx with SN > 199.

CDN2000A-06-32 CMC

3 phase CDN with line voltages L to N/PE=280V and L to

 

L=480V, line current 32A per phase. Auto coupling path selection

 

for EFT, SURGE, RING controlled by TRA2006 and MIG0603INx

 

with S/N >199. Coupling path mode L1 + L2 + L3 + N to PE.

CDN2000A-06-63

Three phase CDN with line voltages L to N/PE=280V and L

 

to L=480V, line current 63A per phase. Automatic coupling

 

path selection for EFT and SURGE controlled by TRA2000,

 

TRA2004, TRA2006, TRA3000 and MIG0603INx with SN > 199.

CDN-A-3P100-480 F

Three phase CDN with line voltages L to N/PE=280V and L to L=480V,

 

line current 100A per phase. Automatic coupling path selection

 

for EFT controlled by TRA2000, TRA2004, TRA2006 and TRA3000.

CDN-A-3P100-480 F-S

Three phase CDN with line voltages L to N/PE=280V and L to L=480V,

 

line current 100A per phase. Automatic coupling path selection for

 

EFT and SURGE controlled by TRA2000, TRA2004, TRA2006, TRA3000

 

and MIG0603INx with SN > 199.

CDN-A-3P100-690 F

Three phase CDN with line voltages L to N/PE=398V and L to L=690V,

 

line current 100A per phase. Automatic coupling path selection for EFT

 

controlled by customized TRA2000, TRA2004, TRA2006 and TRA3000.

 

The generator must be ordered together with the CDN.

CDN-A-3P100-690 F-S

Three phase CDN with line voltages L to N/PE=398V and L to L=690V,

 

line current 100A/Phase. Automatic coupling path selection for EFTand

 

SURGE controlled by customized TRA2000, TRA2004, TRA2006, TRA3000,

 

and MIG0603INx with SN > 199. The generator must be ordered with CDN.

CDN-KIT1000

SURGE coupling-decoupling network for data lines according

 

to IEC 61000-4-5.

CN16

Coupling network for common mode coupling dc, 50/60Hz

 

and sinusoidal up to 150kHz according to IEC 61000-4-16.

CN16T

T-coupling network for telecom lines coupling dc, 50/60Hz

 

 and sinusoidal up to 150kHz according to  IEC 61000-4-16.

CN2000-22-5

One Coupling Module. Serial resistor 40 Ohm and

 

capacitor 0.5µF.

CN2000TT MC

One test pistol and one banana plugged cable with crocodile

 

clip for current injection tests according to IEC 61000-4-5

 

up to 3kA. The test pistol can  be used together with TRA

 

and MIG systems with MC plug outputs on front panel or NW.

CN-BALUN

Balanced / unbalanced transmission line transformer for

 

EFT and 1MHz Damped Sine according to ANSI / IEEE C37.90.

CN-EFT1000

Capacitive coupling clamp 100 Ohm according to IEC 61000-4-4

 

including 1m coax cable with BNC connectors.

DIPS100E

100 Ohm resistor for switching time calibration. Can be used

 

with TRA1000, TRA2000, TRA3000, PFS32, PFS63.

 

100 Ohm +/-5%, 1 kW.

DN2000-22-5

One Decoupling Module for IEC 60255-22-5 application.

 

Inductance 20mH, varistor at the auxiliary side 275V,

 

Imax continuous 3A, intermittant use 10mn 5A.

EFT INSULATION

Set of 2 x 10cm Insulation to EFT circuit according to

 

IEC 61000-4-4.

ESD2000

ESD discharge network 150pF - 330 Ohm. Contact discharge up to

 

10kV, air discharge up to 16kV according to IEC 61000-4-2 Ed.2.

 

Stand available under ESD3000 System, product type ESD-STAND Ed2.

 

For use with TRA2000, TRA2004 and TRA2006 only.

MF1000-1

Test coil 1m x 1m for magnetic field test:

 

50/60Hz according to IEC 61000-4-8,

 

SURGE according to IEC 61000-4-9,

 

Damped oscillatory wave according to IEC 61000-4-10.

MF1000-2

Test coil 1m x 2.6m for magnetic field test:

 

50/60Hz according toIEC 61000-4-8,

 

SURGE according to IEC 61000-4-9,

 

Damped ocillatory wave according to IEC 61000-4-10.

MF1000-3

Test coil 1m x 1m for magnetic field test according to

 

 IEC 61000-4-8 only for short duration 3s 1000A/m.

MF1STAND

Stand to MF1000-1, moveable in all three directions,

 

max height 1.8m. Must be ordered together with the 

 

MF1000-1. Can only be shipped together with the MF1000-1.

MF3STAND

Stand to MF1000-3, moveable in two directions, max.